NP2 Specifications
Rear Panel DIP Switch Selections
Relay 1
Extend – switch 1 is for extending the detector output after the vehicle has left the loop. Switch 1 in the OFF position provides no extension. Switch 1 in the ON position provides a 5 second extension once the vehicle leaves the loop. This extension applies to relay 1 only.
Delay – switch 2 is for providing a 2 second delay, detector will ignore the vehicle until the vehicle has been present over the loop for 2 seconds. Switch 2 in the OFF position provides no delay. Switch 2 in the ON position provides for the 2-second delay. This delay applies to relay 1 only.
Presence Time – switch 3 provides for either a 1 hour presence or permanent presence. Switch 3 in the OFF position provides for 1 hour of presence. Switch 3 in the ON position provides for permanent presence. The above presence settings apply to relay 1 only. (Other options are available).
Relay 2
Pulse Length – switch 4 provides for either a 250mS pulse length or a 500mS pulse length. Switch 4 in the OFF position provides a 250mS (standard) pulse length.
Switch 4 in the ON position provides a 500mS pulse length.
Operating Mode – switch 5 and switch 6 determine the operating mode for Relay 2. The four modes are as follows:
Switch 5 and switch 6 OFF provides pulse-on-entry.
Switch 5 ON & switch 6 OFF provides pulse-on-leaving.
Switch 5 OFF & switch 6 ON provides for presence.
Switch 5 and switch 6 ON provides a fault output.
Front Panel Selections
Sensitivity – controlled by front panel rotary switch.
- 0 = Low sensitivity
- 9 = High sensitivity
Medium sensitivity is used for most applications; this is a setting of 4 or 5. Always use the lowest sensitivity setting that detects the desired vehicles.
Frequency – four separate settings controlled by front panel.
DIP switches.
- 2+1 = High.
- 2+0 = Medium High.
- 1+0 = Medium Low.
- 0+0 = Low.
Reset – front panel reset performs a hard reset of the detector.
Ordering Information:
Unit Voltage Part #
120 VAC NP2-120
Factory Settings
- Set to HI frequency.
- Set to Medium sensitivity (5).
- Extend/Delay in the OFF position.
- Presence time set to 1 hour.
- Pulse length set to 250msec.
- Relay 1 = fail-safe.
- Relay 2 = fail-secure.
Relay Output Rating: 7A 277VAC/30VDC.
Power: 120 VAC
(70mA DC or 1W AC)
Inductance Range: 20uH to 1500uH.
Temperature Range: -30 F to +180 F.
Lead-In Length: up to 2500 ft. with proper lead-in and loop.
Mechanical: 1 3/8”w X 3 3/32”h X 3 ½”l.
Weight: 8 oz.
Supply Voltage – incorrect voltage supplied to the unit will not result in damage, the unit will simply not operate until correct voltage is supplied. No fuses need to be reset.
Indicators – front panel indicators include:
- Power – Green, solid with correct power supplied.
- Relay 1 – Red, solid during detect.
- Relay 2 – Red, solid during detect.
- Fault – Yellow, solid during current fault, flashing for historical fault.
Sensitivity Boost – automatic during detect except in the highest sensitivity setting (9).
Factory Options:
- Presence lengths of 15, 30, 60 minutes or permanent.
- Pulse lengths of 250mS, 500mS, 1, 2 or 4 seconds.
- Extend times of 0, 2, 5 or 10 seconds.
- Delay times of 0, 1, 2 or 4 seconds.
- Relay 1 fail-safe or fail-secure.
- Relay 2 fail-safe or fail-secure.
Note: Bold indicates standard configuration from the factory.
Connector – 11P Amphenol
Pin # Function Color
1 Power (+) Black
2 Power (-) White
3 Relay 2 N.O. Orange
4 Ground Green
5 Relay 1 Com Yellow
6 Relay 1 N.O. Blue
7 Loop Gray
8 Loop Brown
9 Relay 2 Com Red
10 Relay 1 N.C. White/Blk
11 Relay 2 N.C. White/Red
Note: The above connection is shown with correct power supplied and no vehicle present.